Stuffing box packing hardens with age and is one of the most overlooked causes of air leaks, seal-water leaks and bearing failure. Replace all packing rings once a year, not just the ones that are easy to reach. When repacking, stagger the ring joints and never force the gland. During break-in, run for at least 30 minutes and aim for a steady leak of about one drip per second.

November 13, 2026 

Written by Rick Kushinski, Service Manager 

 

Most packing problems can be prevented with regular inspection and maintenance. Modern synthetic packing has also changed the requirements for maintenance, start-up and break-in. This guide covers what to watch for, how to repack correctly and how to break in new packing on your liquid ring vacuum pump.

Warning signs your packing needs attention

Pump has been idle for a long time

Packing in pumps that sit unused for long periods can dry out. Check it before start-up, especially on new or stored pumps.

Bearing temperatures keep climbing

Temperatures that keep rising instead of peaking and settling are a clear warning. Inspect the packing immediately.

Air or seal water leaking at the shaft

Hard, brittle packing no longer seals. Expect air leakage at higher vacuum and seal-water leakage at lower vacuum.

Gland tightened again and again

Repeated tightening overheats the shaft and can crack its metalizing. At that point the pump needs repair.

Why annual stuffing box maintenance matters

As packing ages it becomes hard and brittle and stops sealing against the shaft. The usual response, tightening the gland, makes things worse: friction overheats the shaft and damages it. Changing the packing every year keeps the job simple, because the old packing is still pliable. 

Replace every ring, not just the outer ones. Many pumps that come in for repair have had only the first two or three accessible rings changed. The rings left behind cause the same problems all over again.

Inside the stuffing box

Select a marker to see what each part does and what to check. 

Inside the stuffing box

How to repack a pump step by step

  1. Remove all of the old packing. Every ring comes out, including the inner rings that are hard to reach.
  2. Inspect the shaft and the drip tray. Check the shaft for grooves and make sure the drip tray drain is clear.
  3. Install the first three rings with staggered slits. Offset each ring's slit from the one before it, and use the gland to seat each ring correctly.
  4. Prepare the gland. Cut ¼ in (6 mm) from the new ring and flatten it slightly so the gland enters the stuffing box more easily. Never force the gland in: graphite-impregnated PTFE packing can wear a groove into the shaft.
  5. Install the fourth ring and start the pump. Place the last ring's opening at the bottom of the shaft, start the gland in the stuffing box, then start the pump and adjust.
  6. Add the final ring only if it fits. There must still be a drip, or the packing must run at a temperature you can comfortably keep your hand on.

Start-up and break-in targets

Use these targets when starting a new pump or a pump with new packing. 

 

Check

Target

Gland at start-up

Loose, but not riding on the shaft 

Break-in time

At least 30 minutes, with the packing leaking 

Leak rate

About 1 drip per second 

How to adjust

Gland nuts one flat at a time, both sides of the shaft; one end of the pump at a time 

Wait between adjustments

At least 20 minutes

Pumps that don’t drip

Packing temperature at or below 54 °C (129 °F)

 